Peter Paul Electronics Co., Inc.
Home | Contact Us | Search
Peter Paul
The Valves
Whats New

Valve Info - 3 WAY DIRECTIONAL CONTROL

Pressure Ratings

Series 15 Aluminum 1/8 NPT
3 Way Directional Control - Model 155

Click here for specs
Model &
Type
Max Press
AC DC
Orifice Size
Inlet Exh
CV
Inlet Exh
Lead wire Euro
Connector
1/2" NPT
Conduit
3 Way Directional Control Model 155
300 200
1/32 1/32
.022 .020
155GG2XGM 155GG2XEM 155GG2XCM
200 150
3/64 3/64
.055 .048
155HH2XGM 155HH2XEM 155HH2XCM
100 75
1/16 1/16
.075 .075
155JJ2XGM 155JJ2XEM 155JJ2XCM
75 40
3/32 1/16
.130 .075
155KJ2XGM 155KJ2XEM 155KJ2XCM
75 40
3/32 3/32
.130 .130
155KK2XGM 155KK2XEM 155KK2XCM

Series 20 - Stainless Steel
3 Way Directional Control - Model 25

Click here for specs
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT 1/4 NPT 1/8 NPT 1/4 NPT
REPAIR PACK
500 500 1/32 1/32 .024 .024
25GG7XGV 25GG9ZGV 25GG7XCV 25GG9ZCV
K25GGX
235(400) 235(300) 3/64 3/64 .052 .052
25HH7XGV 25HH9ZGV 25HH7XCV 25HH9ZCV
K25HHX
200(225) 200(225) 1/16 3/64 .095 .052
25JH7XGV 25JH9ZGV 25JH7XCV 25JH9ZCV
K25JHX
150(225) 150(200) 1/16 1/16 .095 .156
25JJ7XGV 25JJ9ZGV 25JJ7XCV 25JJ9ZCV
K25JJX
100(150) 100(125) 3/32 3/32 .156 .156
25KK7XGV 25KK9ZGV 25KK7XCV 25KK9ZCV
K25KKX
100(125) 100 1/8 3/32 .214 .156
25NK7XGV 25NK9ZGV 25NK7XCV 25NK9ZCV
K25NKX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve#.
EXAMPLE: Valve (25GG7XGV-120/60) REPAIR PACK (K25GGX-AC)

Series 20 - Stainless Steel
3 Way Directional Control - Explosion Proof - Model E25

Click here for specs
*Max Oper Press Diff. Orifice Size CV Factor
AC DC
CONDUIT HOUSING (1/2" NPT)
1/8 NPT Ports 1/4 NPT Ports
500 500 1/32 1/32 .024 .024
E25GG7XCCM E25GG9ZCCM
235 (400) 235 (300) 3/64 3/64 .052 .052
E25HH7XCCM E25HH9ZCCM
200 (225) 200 (200) 1/16 3/64 .095 .052
E25JH7XCCM E25JH9ZCCM
150 (225) 150 (200) 1/16 1/16 .095 .095
E25JJ7XCCM E25JJ9ZCCM
100 (150) 100 (125) 3/32 3/32 .156 .156
E25KK7XCCM E25KK9ZCCM
100 (125) 100 1/8 3/32 .214 .156
E25NK7XCCM E25NK9ZCCM

Series 30 - Brass
3 Way Directional Control - Model 35

Click here for specs
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/8 NPT Ports 1/8 NPT Ports
REPAIR
PACK
300 300 1/32 1/32 .024 .024
35GG5XGV 35GG5XCV
K35GGX
175 175 3/64 1/16 .052 .095
35HJ5XGV 35HJ5XCV
K35HJX
125 125 1/16 1/16 .095 .095
35JJ5XGV 35JJ5XCV
K35JJX
75 75 3/32 3/32 .160 .160
35KK5XGV 35KK5XCV
K35KKX
50 50 1/8 3/32 .275 .160
35NK5XGV 35NK5XCV
K35NKX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve #.
EXAMPLE: Valve (35GG5XGV-120/60) REPAIR PACK (K35GGX-AC)

Series 50 - Stainless Steel
3 Way Directional Control - Model 55

Click here for specs
*Max Oper Press Diff. Orifice Size CV Factor
AC DC

Inlet Exh

Inlet Exh
GROMMET HOUSING
1/8 NPT Ports
CONDUIT HOUSING
1/8 NPT Ports
REPAIR
PACK
250 200 1/32 1/32 .022 .020
55GG8XGB 55GG8XCB
K55GGX
200 100 3/64 3/64 .055 .048
55HH8XGB 55HH8XCB
K55HHX
100 50 1/16 1/16 .075 .075
55JJ8XGB 55JJ8XCB
K55JJX
75 25 3/32 1/16 .156 .075
55KJ8XGB 55KJ8XCB
K55KJX
75 40 3/32 3/32 .150 .150
55KK8XGB 55KK8XCB
K55KKX
45 25 1/8 3/32 .230 .150
55NK8XGB 55NK8XCB
K55NKX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve #.
EXAMPLE: Valve (55GG8XGV-120/60) REPAIR PACK (K55GGX-AC)

Series 50 - Stainless Steel
3 Way Directional Control - Explosion Proof - Model E55

Click here for specs
*Max. Oper
Press Diff.
AC DC
Orifice
Size
Inlet Exh
CV
Factor
Inlet Exh
CONDUIT HOUSING (1/2" NPT)
Housing available in all Stainless Steel construction
1/8 NPT Ports
300 200 1/32 1/32 .022 .020
E55GG8XCCM
200 100 3/64 3/64 .055 .048
E55HH8XCCM
100 50 1/16 1/16 .075 .075
E55JJ8XCCM
75 25 3/32 1/16 .156 .075
E55KJ8XCCM
65 20 3/32 3/32 .150 .150
E55KK8XCCM
45 25 1/8 3/32 .230 .150
E55NK8XCCM

SERIES 58 - MODEL 585
3 WAY DIRECTIONAL CONTROL - 3.5 Watt

Click here for specs
Max Press
AC & DC
Orifice Size
Inlet Exh
CV
Inlet Exh
Lead Wire
Unit
Micro Din
Unit
300 psi
.6 MM* .6 MM
0.010 0.010
585AA15PG 585AA15PE
200 psi
.8 MM* .8 MM
0.020 0.020
585FF15PG 585FF15PE
50 psi
1.0 MM* 1.0 MM
0.030 0.030
585MM15PG 585MM15PE
35 psi
1.2 MM* 1.2 MM
0.034 0.034
585WW15PG 585WW15PE
*NORMALLY CLOSED PORT

Series 70 - Stainless Steel
3 Way Directional Control - Model 75

Click here for specs
*Max Oper Press Diff. Orifice Size CV Factor
AC DC Inlet Exh Inlet Exh
GROMMET HOUSING CONDUIT HOUSING
1/4 NPT Ports 1/4 NPT Ports
REPAIR
PACK
250 250 3/32 3/32 .22 .22
75KK9ZGV 75KK9ZCV
K75KKX
175 175 1/8 1/8 .35 .35
75NN9ZGV 75NN9ZCV
K75NNX
125 125 5/32 5/32 .45 .45
75OO9ZGV 75OO9ZCV
K75OOX
75 75 3/16 3/16 .50 .50
75PP9ZGV 75PP9ZCV
K75PPX
When Ordering Valves or Repair Packs Add Voltage and Frequency to Complete Valve #.
EXAMPLE: Valve (75NN9ZGV-120/60) REPAIR PACK (K75NNX-AC)